Return to flip book view

Siemens Plug-On Neutral Loadcenter_WES

Page 1

Plug On Neutral Load Centers and Electronic Breakers Simple Spacious Secure Installs just like any other circuit breaker Now without the pigtail No new wiring practice or installation method required usa siemens com loadcenters

Page 2

You have come to know Siemens solutions for their durability innovation and safety attributes This continues with the plug on neutral load center with electronic breakers to provide a more secure connection resulting in a more confident installation Simple Quicker breaker installation Spacious Small electronic breaker footprint Secure Same reliable installation method A Siemens Advantage 2 Wiring made easier with the neutral lug removed on CAFCI breakers Same great features as PL and ES load centers Design allows for neutral terminal accessibility Over 4 inches of wire bending space Neutral clip is the same as line side Durable hook rail

Page 3

With an overall smaller electronic breaker footprint the plug on neutral load center still gives you over 4 of wire bending space which allows for a simpler cleaner and faster path to a finished project The plug on neutral load center has the same great features of the PL and ES line plus an integrated neutral bus a Convertible Bonding Screw Visible Neutrals Insta Wire Invertible Durable Hook Rails Integrated Neutral Bus a PN panels are convertible and come with two ground bars SN panels come with one ground bar 3

Page 4

Plug on neutral breaker offering 1 and 2 pole CAFCI 1 pole Dual Function CAFCI GFCI 1 pole GFCI Combination Type AFCI QA115AFCN 1 pole QA120AFCN Q215AFCN 2 pole Features Load Lug s only on the CAFCI breakers LED indicators for troubleshooting Insta Wire connectors Technical Data 10 000 AIC 120V UL Listed HACR and SWD rated Q220AFCN Dual Function Q115DFN 1 pole Q120DFN GFCI Class A 5mA QF115AN QF120AN 1 pole QF125AN QF130AN Note Both plug on neutral and existing pigtail breakers are listed for use in plug on neutral load centers The new plug on neutral load center is compatible with existing surge solutions including the QSA breaker and FirstSurge stand alone units Additionally there are four panels offered with a factory installed FirstSurge unit FirstSurge Surge Protection Device QSA Circuit Breaker and Surge Protection Device 4

Page 5

CAFCI Dual Function CAFCI breakers now have a single lug only The branch neutral conductor is returned to the neutral terminal bar CAFCI breakers can be installed in the same manner as a thermal magnetic standard breaker This allows the installer to land ground and neutral conductors before installing the breaker and power conductor Plug on neutral breakers are designed using the existing line side clip to make the neutral connection This clip is time tested and offers a secure connection 5

Page 6

PN Series 1 phase Main Breaker Convertible Plug On Neutral Load Centers h 1 phase 3 wire 120 240 Volts AC Main Breaker Convertible Load Centers a 100 225 Amperes Indoor Enclosure NEMA Type 1 Outdoor Enclosure NEMA Type 3R Amp Rating No of Spaces No of Circuits Catalog Number Enclosure Height inches s Catalog Number Enclosure Height inches d 100 12 24 PN1224B1100C 18 PNW1224B1100C 21 100 16 32 PN1632B1100C 21 PNW1632B1100C 23 100 20 20 PN2020B1100C 21 PNW2020B1100C 27 100 20 40 PN2040B1100C 21 100 24 24 PN2424B1100C 24 100 30 30 PN3030B1100C 26 100 30 48 PNW3048B1100C 29 125 30 30 PN3030B1125C 26 125 30 48 PNW3048B1125C 29 150 8 16 PNW0816B1150TC g 23 150 20 40 PN2040B1150C 24 PNW2040B1150C 27 150 30 30 PN3030B1150C 30 150 30 48 PNW3048B1150C 35 200 8 16 PNW0816B1200TC g 23 200 20 40 PN2040B1200C 26 PNW2040B1200C 27 200 30 48 PN3048B1200 f 30 200 30 48 PN3048B1200C 30 PNW3048B1200C 35 200 40 40 PN4040B1200 f 36 200 40 40 PN4040B1200C 36 PNW4040B1200C 38 200 40 60 PN4060B1200 f 36 200 40 60 PN4060B1200C 36 200 54 82 PN5482B1200C 42 225 42 64 PN4264B1225C 39 PNW4264B1225C 38 225 54 82 PN5482B1225C 43 a s d f g h 6 Copper Bus 60 75 C Rated Factory installed 22KAIC main breaker Suitable for use as service equipment Indoor enclosures are 14 1 4 wide by 3 7 8 deep Outdoor enclosures are 14 1 2 wide by 4 1 4 deep Includes all PN series features with aluminum bus Feed thru lugs Available made to order in white by adding W to the end of the catalog number

Page 7

PN Series 1 phase Main Lug Convertible Plug On Neutral Load Centers h 1 phase 3 wire 120 240 Volts AC Main Lug Convertible Load Centers d 125 225 Amperes Indoor Enclosure NEMA Type 1 Copper Bus 60 75 C Rated Outdoor Enclosure NEMA Type 3R Amp Rating No of Spaces No of Circuits Catalog Number Enclosure Height inches a Catalog Number Enclosure Height inches s 125 12 12 PN1212L1125C 18 PNW1212L1125C 21 125 12 24 PN1224L1125C 18 PNW1224L1125C 21 125 16 32 PN1632L1125C 21 PNW1632L1125C 23 125 20 20 PN2020L1125C 21 125 20 40 PN2040L1125C 21 125 24 48 PN2448L1125C 24 125 30 48 PN3048L1125C 26 PNW3048L1125C 29 125 40 40 PN4040L1125C 36 150 20 40 PN2040L1150C 24 PNW2040L1150C 27 200 8 16 PNW0816L1200TC g 23 200 12 24 PN1224L1200C 21 PNW1224L1200C 23 200 20 40 PN2040L1200C 26 PNW2040L1200C 27 200 24 48 PN2448L1200C 30 200 30 30 PN3030L1200C 30 200 30 48 PN3048L1200 f 30 200 30 48 PN3048L1200C 30 PNW3048L1200C 35 200 40 40 PN4040L1200 f 36 200 40 40 PN4040L1200C 36 PNW4040L1200C 38 200 40 60 PN4060L1200C 36 225 12 24 PNW1224L1225C 27 225 42 64 PN4264L1225C 39 PNW4264L1225C 38 225 54 82 PN5482L1225C 43 a s d f g h Indoor enclosures are 14 1 4 wide by 3 7 8 deep Outdoor enclosures are 14 1 2 wide by 4 1 4 deep 125A load centers will accept MBK100A and MBK125A 150A load centers will accept MBK150A 200A load centers will accept MBK200A and MBK150A 225A load centers will accept MBK225A MBK200A MBK150A Includes all PN series features with aluminum bus Feed thru lugs Available made to order in white by adding W to the end of the catalog number 7

Page 8

SN Series 1 phase Main Breaker Plug On Neutral Load Centers g 1 phase 3 wire 120 240 Volts AC Main Breaker Load Centers a 100 225 Amperes Indoor Enclosure NEMA Type 1 Aluminum Bus 60 75 C Rated Outdoor Enclosure NEMA Type 3R Amp Rating No of Spaces No of Circuits Catalog Number Enclosure Height inches s Catalog Number Enclosure Height inches d 100 12 24 SN1224B1100 18 SNW1224B1100 21 100 16 32 SN1632B1100 21 SNW1632B1100 23 100 20 20 SN2020B1100 21 SNW2020B1100 27 100 20 40 SN2040B1100 21 100 24 48 SN2448B1100 24 100 30 30 SN3030B1100 26 100 30 48 SN3048B1100 26 125 12 24 SNW1224B1125 21 125 16 32 SN1632B1125 21 125 20 40 SNW2040B1125 27 125 24 24 SN2424B1125 24 SNW2424B1125 27 125 30 30 SN3030B1125 26 125 30 48 SN3048B1125 26 SNW3048B1125 29 150 16 32 SN1632B1150 24 150 20 40 SN2040B1150 24 SNW2040B1150 27 150 24 48 SN2448B1150 26 150 30 30 SN3030B1150 30 150 30 48 SN3048B1150 30 SNW3048B1150 35 200 40 40 SNW4040B1150 38 200 8 16 SNW0816B1200T f 23 200 12 24 SNW1224B1200 23 200 16 32 SN1632B1200 24 200 20 40 SN2040B1200 26 SNW2040B1200 27 200 24 48 SN2448B1200 30 200 30 48 SN3048B1200 30 SNW3048B1200 35 200 40 40 SN4040B1200 36 SNW4040B1200 38 200 40 60 SN4060B1200 36 200 42 64 SN4264B1200 39 200 54 82 SN5482B1200 42 225 42 64 SN4264B1225 39 SNW4264B1225 38 225 54 82 SN5482B1225 43 a Factory installed 22KAIC main breaker Suitable for use as service equipment s Indoor enclosures are 14 1 4 wide by 3 7 8 deep d Outdoor enclosures are 14 1 2 wide by 4 1 4 deep 8 f Feed thru lugs g Available made to order in white by adding W to the end of the catalog number

Page 9

SN Series 1 phase Main Lug Plug On Neutral Load Centers f 1 phase 3 wire 120 240 Volts AC Main Lug Load Centers 100 225 Amperes Indoor Enclosure NEMA Type 1 Aluminum Bus 60 75 C Rated Outdoor Enclosure NEMA Type 3R Amp Rating No of Spaces No of Circuits Catalog Number Enclosure Height inches a Catalog Number Enclosure Height inches s 125 12 12 SN1212L1125 18 SNW1212L1125 21 125 12 24 SN1224L1125 18 SNW1224L1125 21 125 16 32 SN1632L1125 21 SNW1632L1125 21 125 20 20 SN2020L1125 21 125 20 40 SN2040L1125 21 SNW2040L1125 23 125 24 24 SN2424L1125 24 SNW2424L1125 27 125 24 48 SN2448L1125 24 125 30 48 SN3048L1125 26 SNW3048L1125 29 125 40 40 SN4040L1125 30 150 16 32 SN1632L1150 21 150 20 40 SN2040L1150 24 SNW2040L1150 27 150 24 48 SN2448L1150 26 200 8 16 SNW0816L1200T d 23 200 12 24 SN1224L1200 21 SNW1224L1200 21 200 20 40 SN2040L1200 26 SNW2040L1200 27 200 24 48 SN2448L1200 26 200 30 30 SN3030L1200 30 200 30 48 SN3048L1200 30 SNW3048L1200 29 200 40 40 SN4040L1200 36 SNW4040L1200 35 225 12 24 SNW1224L1225 21 225 40 60 SN4060L1225 36 225 42 64 SN4264L1225 36 SNW4264L1225 38 225 54 82 SN5482L1225 42 a Indoor enclosures are 14 1 4 wide by 3 7 8 deep s Outdoor enclosures are 14 1 2 wide by 4 1 4 deep d Feed thru lugs f Available made to order in white by adding W to the end of the catalog number 9

Page 10

Specialty Main Lug and Main Breaker Plug On Neutral Load Centers 1 phase 3 wire 120 240 Volts AC Factory Installed FirstSurge Load Centers Indoor Enclosure NEMA Type 1 Amp Rating No of Spaces No of Circuits Catalog Number Enclosure Height inches Surge Protection 200 30 48 PN3048B1200S14 36 140kA 200 40 60 PN4060B1200S14 42 140kA 200 30 48 SN3048B1200S06 36 60kA 200 40 60 SN4060B1200S06 42 60kA 500 Kcmil Lug Load Center Indoor Enclosure NEMA Type 1 Amp Rating No of Spaces No of Circuits Catalog Number Enclosure Height inches 200 30 48 SN3048L1200L50 36 Selectable Main Load Centers Indoor Enclosure NEMA Type 1 Outdoor Enclosure NEMA Type 3R Amp Rating No of Spaces No of Circuits Catalog Number Enclosure Height inches Catalog Number Enclosure Height inches 125 24 24 SN2424C1125 24 SNW2424C1125 27 200 20 40 SN2040C1200 26 SNW2040C1200 27 200 30 48 SN3048C1200 30 SNW3048C1200 35 200 40 40 SN4040C1200 36 SNW4040C1200 38 10

Page 11

Notes 11

Page 12

Published by Siemens 2019 Siemens Industry Inc 5400 Triangle Parkway Norcross GA 30092 Siemens Technical Support 1 800 333 7421 info us siemens com Printed in USA CP Order No RPBR PLUGO 1019 All Rights Reserved 2019 Siemens Industry Inc usa siemens com loadcenters The technical data presented in this document is based on an actual case or on as designed parameters and therefore should not be relied upon for any specific application and does not constitute a performance guarantee for any projects Actual results are dependent on variable conditions Accordingly Siemens does not make representations warranties or assurances as to the accuracy currency or completeness of the content contained herein If requested we will provide specific technical data or specifications with respect to any customer s particular applications Our company is constantly involved in engineering and development For that reason we reserve the right to modify at any time the technology and product specifications contained herein